Scanntronik Mugrauer USB Devices Driver Download For Windows 10

-->

Summary

If the device is a USB Type-C device, confirm that the applicable USB and alternate modes are functional. Using ETW to log issues. See How to capture a USB event trace with Logman. Reporting test results. Provide these details: The list of tests (in order) that were performed before the failed test. Ensure that you are using the most current USB 3.0 Drivers (where applicable) as provided by Intel (or your chipset manufacturer). Ensure that your computer has all of the Windows Updates installed. The following 'SoftFOX' software release is a 32/64-bit application, especially designed for the 'Windows' operating systems: Microsoft Windows© XP, Vista, 7, 8, 10 or a newer version. Using the software with an older 'Windows' operating system is not recommended. Usb Scanner free download - Panda USB Vaccine, Epson TWAIN USB Scanner Driver, USB Drive Antivirus, and many more programs. To “Windows Update” with “No, not this time” and cl ick on the button “Next”. In the following window, choose the option “Install from a list or specific location” if you’re using Windows XP or “Search for a suitable driver for my device” if you’re using Windows 2000. Once more click on the button “Next”.

  • Automated testing by using USB Type-C ConnEx
  • USB Type-C interoperability test procedures in Windows 10: functional testing (FT) and stress testing (ST).
  • Diagnostic procedures and tips to confirm scenarios, such as device addition and removal.

Applies to

  • Windows 10

Specifications and procedures**

Note

Some information relates to pre-released product which may be substantially modified before it's commercially released. Microsoft makes no warranties, express or implied, with respect to the information provided here.

The MUTT Connection Exerciser Type-C (USB Type-C ConnEx) hardware board is a custom shield for the Arduino board. The shield provides a four-to-one switch to automate interoperability tests for USB Type-C scenarios.

This topic provides guidelines to automate the testing of systems, devices, docks with USB Type-C connectors and their interoperability with the Windows operating system. You can test hardware that belong to one of the following categories:

  • System: Desktops, laptops, tablets, servers, or phones running a SKU of a version of the Windows operating system with an exposed USB Type-C port.
  • Dock: Any USB Type-C device that exposes more than one port.
  • Device: Any USB device with a Type-C port that can be attached to a system or dock. This category includes traditional USB devices as well as devices that support the accessory and alternate modes as defined in the USB Type-C specification.

Hardware requirements

To perform the USB Type-C interoperability test procedures by using USB Type-C ConnEx, you need:

  • System under test (SUT)

    Desktops, laptops, tablets, servers, or phones with at least one exposed Type-C USB port.

  • Arduino Mega 2560 R3

    Arduino Mega 2560 R3 is used as the microcontroller for the test setup.

  • Power adapter for the Arduino Mega 2560 R3 microcontroller.

  • USB Type-C ConnEx

    The shield has one male USB Type-C port (labeled J1) to which the SUT is connected. The shield also has four other USB ports (labeled J2, J3, J4, J6) to which devices can be attached that act as peripherals to the SUT. The shield monitors amperage and voltage being drawn from the SUT. You can buy this board from MCCI or JJG Technologies.

  • USB A-to-B cable

    You will use this cable to connect a PC to the microcontroller in order to update the firmware on the microcontroller to run tests.

  • Peripheral USB devices

    Any USB device with a USB Type-C port that can be attached to the SUT. This category includes traditional USB devices and other devices that support the accessory and alternate modes as defined in the USB Type-C specification.

  • USB charger

    USB Type-C that supports USB Type-C current requirements and optionally USB Power Delivery. You also need a USB Micro-B charger for J6.

  • Proxy controller

    The USB Type-C ConnEx can be controlled by using a proxy for running the tests. The proxy controller can be one of these entities:

    • Secondary desktop PC or a laptop.

      The proxy controller communicates with a mobile SUT, the microcontroller to load the firmware.

    • SUT by using a secondary USB port.

    • SUT by using a 3.5mm audio jack.

      In this set up, you need:

      • DTMF shield to run tests on SUTs with a single USB Type-C port. DTMF provides the ability to control the shield from a single-port device with an audio jack after the initial flash of the firmware has been completed.

      • 4-pin male-to-male audio cable used to connect the DTMF shield to the SUT. This allows the SUT to control the USB Type-C shield during testing.

Software requirements

Make sure you meet these requirements:

  • Your SUT must have the version of the Windows operating system with which you want to test interoperability.

  • The proxy controller must be running Windows 10.

  • and install the latest MUTT software package on the proxy controller.The package is a suite of tools used to run tests with USB Type-C ConnEx. It includes utilities to update the firmware, switch between the peripheral ports, and send requests to simulate test cases. It also contains test driver packages that test the functionality of the buses, its controller, and devices connected to the bus.

  • For UCSI based systems we strongly recommended testing with some additional settings to help discover UCSI firmware bugs. This setting will make UCSI firmware issues discoverable and is highly recommended for testing purposes only. Please see Debugging USCI firmware failures in this blog post.

  • Installation of the test tools requires an elevated command window.

    To open an elevated command window, the user must be a member of the Administrators group on the proxy controller. To open an elevated Command Prompt window, create a desktop shortcut to Cmd.exe, select and hold (or right-click) the Cmd.exe shortcut, and select Run as administrator.

USB Type-C ConnEx tools

Here are the tools in MUTT software package that are specific to USB Type-C ConnEx

ToolDescription
ConnExUtil.exeCommand line tool for exercising USB Type-C ConnEx features.
CxLoop.cmdConnects and disconnects each port once.
CxStress.cmdRandomized stress script.
CxPower.cmdCaptures power data (voltage and amperage) over a period of time and sends the output to a CSV file.

For information about all other tools, see Tools in the MUTT software package.

Get started

Follow this procedure to set up your test environment.

The configuration should be similar to this image. Note that the USB Type-C port on the microcontroller provides control over USB Type-C ConnEx when connected to a PC.

In these steps, you will connect the hardware pieces, update the firmware on the microcontroller, and validate the installation. The DTMF shield provides control over USB Type-C ConnEx when connected to the audio port of a phone or tablet.

  1. Connect the microcontroller to the USB Type-C shield.

    If the USB Type-C ConnEx did not come assembled, then continue with step 1. If your USB Type-C ConnEx has been assembled, then proceed to step 2.

    Caution

    This step must be performed carefully because the pins bend easily.

    1. Align the pins of the USB Type-C shield with the receptors on the microcontroller by making sure that the boards are level to each other.

    2. Gently press the two boards together. Be careful not to bend the pins on the shield.

      Your assembled unit should be similar to this image:

  2. Power the USB Type-C ConnEx from the attached microcontroller by using either the USB Type-B (connected to the proxy controller) or from an external power adapter. The LCD display is similar to this image:

    After five seconds, the LCD display shows the current and voltage.

    If you do not the see display as shown in the previous image, make sure your have assembled the unit correctly.

  3. Update the microcontroller with the USB Type-C ConnEx firmware.

    • Open an elevated Command Prompt window.

    • Navigate to the location of the MUTT software package, such as C:Program Files (x86)USBTest<arch>.

    • Run the following command:

      MuttUtil.exe –UpdateTabFirmware

  4. Plug in the SUT to the male USB Type-C port (labeled J1) on the shield.

    Caution The J1 connector requires additional support when connecting the SUT. The connector is not sturdy enough to sustain the weight of a device or by itself.

  5. Attach the peripherals to the USB ports labeled J2, J3, J4, J6.

  6. Attach the proxy controller to the microcontroller.

    • If the proxy controller is a desktop PC or laptop, establish connection over USB. Connect the USB Type-B port on the microcontroller to a USB port on the proxy controller, as shown in the preceding image.
    • If the proxy controller is a mobile SUT, establish connection by using the audio port. For this connection, you need the DTMF shield.
      1. Connect the DTMF shield to the assembled unit as shown in this image:

      2. Connect the audio port of the shield to the audio port on the SUT by using a 4-pin male-to-male audio cable.

        Your setup should be similar to this image:

  7. Make sure USB Type-C ConnEx is recognized by Device Manager on the proxy controller.

    1. Right-click the Start button in the task bar and select Device Manager.

    2. Expand the Ports (COM & LPT) node and note the COM port that is used by the microcontroller. In this example, it is connected to COM 4.

ConnExUtil.exe

64-bit

Here are the command line options that ConnExUtil.exe supports for controlling the USB Type-C ConnEx board.

Use caseOptionDescription
Device Discovery

List all devices connected to USB Type-C ConnEx

/listFor USB connected devices, this option lists the device instance path. For audio connected devices it shows Audio.

To view audio devices, use this in combination with the /all parameter. Lists with 1-based index that can be used for input to the /# parameter.

Device Selection

Select all devices connected to USB Type-C ConnEx, including audio.

/allOptional.

Without this parameter, the utility addresses USB connected devices. Use this parameter only if an audio connected device is in use. Audio discovery is time consuming and disabled by default.

Device Selection

Select a specific device connected to USB Type-C ConnEx ‘n’.

/#n(Optional)

Input n is a 1-based index of the available devices connected to USB Type-C ConnEx which can be viewed by using the /list parameter. Without this parameter, the default behavior is to run each command on all USB Type-C ConnEx boards.

Device Command/setPortpSwitch to the specified port p.

Connect a port either by specifying number (1 – 4) or by name (J2, J3, J4, J6).

0 disconnects all ports.

Device Command/getPortRead the currently connected port.
Device Command

Read amperage/voltage information

/volts

/amps

/version

Read the current voltage.

Read the current amperage.

Read the device version.

Device Command

Enable SuperSpeed

/SuperSpeedOnEnables SuperSpeed globally for current and future connections until a /SuperSpeedOff command is sent.

SuperSpeed is enabled by default.

If SuperSpeed is disabled, and port 1 or 2 is connected, this command triggers a reconnect at SuperSpeed.

Device Command

Disable SuperSpeed

/SuperSpeedOffDisables SuperSpeed globally for current and future connections until a /SuperSpeedOn command is sent or the device is reset.

If SuperSpeed is enabled and port 1 or 2 is connected, this command triggers a reconnect with SuperSpeed lines disabled.

Set command delay

/setDelaytSets command delay t in seconds.

Setting a command delay will cause the next /setPort or /SuperSpeed{On/Off} command to be delayed by t seconds where t ranges from 0 to 99. This is a one-time setting, only the next command is delayed. Sending multiple commands before the delay timer has expired is not supported.

Set disconnect timeout in milliseconds

/setDisconnectTimeouttSet a disconnect timeout for the next non-zero /setPort command. On the next connect event, the port will only remain connected for t milliseconds before disconnecting. This is a one-time setting, only the next connect event will be automatically disconnected. Allowed range is from 0 – 9999 ms.

Batch Command:

Output power measurements to a .csv file.

/powercsvAppend the current power measurements and timestamp into power.csv The first run creates power.csv. On subsequent runs appends data to this file.

Rename or delete the file to start fresh data capture. Each run appends a line with the following format: <index>,<time>,<volts>,<amps>.

index is the device index given by /list, so multiple devices may be monitored simultaneously.

time is the raw timestamp in seconds.

volts and amps are recorded to two decimal places.

This data may be captured over long periods of time and plotted in a spreadsheet application, see the cxpower.cmd script.

Batch Command:

Run unit test of major functionality
/testTests all the major functionality of the device. Use for basic validation of the functionality of the device. If this command fails, please power cycle the device and update the firmware.

Batch Command:

Basic demo of the port switching sequence.
/demo dLoop through all ports one time, with d second delay on each port

Writes the port number, volts and amps on each port into demoresult.txt.

Sample Commands

Connect to a port

Alternatively use the port name as printed on the board:

Disconnect all ports

Loop through all ports

Scripts for controlling the USB Type-C ConnEx board

These scripts exercise the control interface supported by ConnExUtil.exe to run sequential and stress type tests with the USB Type-C ConnEx through the command line. All of these scripts support the optional command line parameter audio to indicate that the USB Type-C ConnEx board is connected over the 3.5 mm audio interface. By default they will only attempt to use USB connected boards.

Simple connect / disconnect sequence: CXLOOP.CMD

Connects and disconnects the SUT to and from each port (1-4) and pauses on each port prompting the tester to validate the connection on that port.

Random connect / disconnect loop: CXSTRESS.CMD

Connects and disconnects the SUT to and from each port at random for a random interval of 0.0-5.0 seconds in an infinite loop. When connecting to the USB Type-C ports it will randomly enable or disable SuperSpeed connection on that port, and will randomly instruct the board to disconnect quickly on that port at some random interval 0 – 999 ms.

The command line parameter C causes the script to only switch between the USB Type-C ports and the disconnected state. A numeric command line parameter resets the maximum random interval between switches from the default of 5.0 seconds to the input value in seconds. Parameters may be passed in any order.

Long running power measurement: CXPOWER.CMD

Saves the amperage and voltage reported by the USB Type-C ConnEx to output file power.csv at 2 second intervals. The data is formatted as comma-separated variables as follows:

index,time,volts,amps

index is the device index given by the ConnExUtil.exe /list command so multiple devices may be monitored simultaneously.

time is the raw timestamp in seconds.

volts and amps are recorded to 2 decimal places.

After capture is complete, this data may be post processed into charts showing power consumption over time, for example the power consumption for the duration of a battery charge cycle. A numeric command line parameter resets the default measurement interval of 2 seconds to the input value in seconds.

About test cases

The USB Type-C interoperability test procedures are divided into two sections: functional testing (FT) and stress testing (ST). Each test section describes the test case and identifies the category that applies to the test. The product must be tested against the entire applicable category. Certain test cases contain links to relevant hints and tips for additional information. This section is focused on USB Type-C functionality and experience. A USB Type-C solution may contains other USB components such as a USB hub or USB controller. Detailed testing of USB hubs and controllers is covered in both the USB-IF's xHCI interoperability test procedures and the Windows Hardware Certification Kit.

Scanntronik Mugrauer Usb Devices Driver Download For Windows 10 64-bit

These test cases are based on the ConnExUtil commands and example scripts Scripts for controlling the USB Type-C ConnEx board. The test cases refer to the scripts. Customize the scripts as required for your test scenario.

Device Enumeration
Confirms that core aspects of device enumeration are functional.

Alternate Mode Negotiation
Confirms supported alternate modes.

Charging and power delivery (PD)
Confirms charging with USB Type-C.

Role Swap
Confirms role swap.

The stress testing section describes procedures for stress and edge case scenarios, which test device stability over a period of time. Stress testing does require a custom device (the SuperMUTT) for legacy USB validation (non USB Type-C). Additional testing and automation can be achieved with the upcoming USB Type-C test device.

Device Enumeration
Confirms that core aspects of device enumeration are functional.

Charging and power delivery (PD)
Confirms charging with USB Type-C.

FT Case 1: Device Enumeration

PortDevice
J1SUT.
J2PC with USB Type-C port that is connected by using a USB Type-C cable.
J3USB Type-C charger.
J4USB Hub (SuperSpeed or high speed) with a mouse connected downstream.
J6PC with USB Type-A port cable connected by using a USB Type-A to USB Micro-B cable.
  1. Power off the SUT.
  2. Connect the SUT to the port labeled as J1 on USB Type-C ConnEx.
  3. Connect the proxy controller to USB Type-C ConnEx.
  4. Connect peripherals to USB Type-C ConnEx.
  5. Power on the SUT and log on to Windows.
  6. At an elevated Command prompt, run the CXLOOP.CMD script. When script pauses, confirm the newly activated peripheral is operational.
  7. Reverse the orientation of USB Type-C cable and repeat step 5 - 7.

For configuration images related to step 2 -4, see Get started....

FT Case 2: Alternate Mode Negotiation

PortDevice
J1SUT.
J2DisplayPort to USB Type-C dongle.
J3USB Type-C charger.
J4USB Hub (SuperSpeed or high speed) with a flash drive connected downstream.
J6PC with USB Type-A port cable connected by using a USB Type-A to USB Micro-B cable.
  1. Power off the SUT.
  2. Connect the SUT to the port labeled as J1 on USB Type-C ConnEx.
  3. Connect the proxy controller to USB Type-C ConnEx.
  4. Connect peripherals to USB Type-C ConnEx.
  5. Power on the SUT and log on to Windows.
  6. At an elevated Command prompt, run the CXLOOP.CMD script. When script pauses, confirm the newly activated peripheral is operational.
  7. Reverse the orientation of USB Type-C cable and repeat step 5 - 7.

For configuration images related to step 2 -4, see Get started....

FT Case 3: Charging and power delivery (PD)

PortDevice
J1SUT.
J2None.
J3USB Type-C charger.
J4USB mouse.
J6USB Micro-B charger.
  1. Power off the SUT.

  2. Connect the SUT to the port labeled as J1 on USB Type-C ConnEx.

  3. Connect the proxy controller to USB Type-C ConnEx.

  4. Connect peripherals to USB Type-C ConnEx.

  5. Power on the SUT and log on to Windows.

  6. At an elevated Command prompt, run the CXLOOP.CMD script. When script pauses, confirm the newly activated peripheral is operational.

  7. Reverse the orientation of USB Type-C cable and repeat step 5 - 7.

  8. Connect USB Type-C ConnEx to port J2.

    ConnExUtil.exe /setPort 2

  9. If SUT contains more than one USB Type-C port, connect two USB Type-C ports on the same system with a USB Type-C cable.

    Confirm that the SUT is not charging (itself).

    Confirm that the LCD reading of power matches the expectations of the wall adapter.

  10. Replace the USB Type-C charger connected to J3 with another USB Type-C charger from a different manufacturer.

    Confirm the device is receiving current.

For configuration images related to step 2 -4, see Get started....

FT Case 4: Role Swap

PortDevice
J1SUT.
J2PC with USB Type-C port that is connected by using a USB Type-C cable.
J3None.
J4USB flash drive.
J6PC with USB Type-A port cable connected by using a USB Type-A to USB Micro-B cable.
  1. Power off the SUT.

  2. Connect the SUT to the port labeled as J1 on USB Type-C ConnEx.

  3. Connect the proxy controller to USB Type-C ConnEx.

  4. Connect peripherals to USB Type-C ConnEx.

  5. Power on the SUT and log on to Windows.

  6. At an elevated Command prompt, run the CXLOOP.CMD script. When script pauses, confirm the newly activated peripheral is operational.

  7. Reverse the orientation of USB Type-C cable and repeat step 5 - 7.

  8. Connect USB Type-C ConnEx to port J2.

    Confirm role swap. The Amperage shown on the LCD screen indicates power roles. +ve if J1 is the power sink; -ve if J1 is the power source.

  9. Perform necessary steps to swap data roles and confirm current roles of each system have changed.

For configuration images related to step 2 -4, see Get started....

ST Case 1: Device Enumeration

PortDevice
J1SUT.
J2PC with USB Type-C port that is connected by using a USB Type-C cable.
J3USB Type-C charger.
J4USB Hub (SuperSpeed or high speed) with a mouse connected downstream.
J6PC with USB Type-A port cable connected by using a USB Type-A to USB Micro-B cable.
  1. Power off the SUT.

  2. Connect the SUT to the port labeled as J1 on USB Type-C ConnEx.

  3. Connect the proxy controller to USB Type-C ConnEx.

  4. Connect peripherals to USB Type-C ConnEx.

  5. Power on the SUT and log on to Windows.

  6. At an elevated Command prompt, run the CXSTRESS.CMD for 12 hours.

    Terminate the script by pressing Ctrl-C.

  7. Perform the steps described in FT Case 1: Device Enumeration.

For configuration images related to step 2 -4, see Get started....

ST Case 2: Charging and power delivery (PD)

PortDevice
J1SUT.
J2None.
J3USB Type-C charger.
J4USB mouse.
J6USB Micro-B charger.
  1. Power off the SUT.

  2. Connect the SUT to the port labeled as J1 on USB Type-C ConnEx.

  3. Connect the proxy controller to USB Type-C ConnEx.

  4. Connect peripherals to USB Type-C ConnEx.

  5. Power on the SUT and log on to Windows.

  6. At an elevated Command prompt, run the CXSTRESS.CMD for 12 hours. .

    Terminate the script by pressing Ctrl-C.

  7. Perform the steps described in FT Case 3: Charging and power delivery (PD).

For configuration images related to step 2 -4, see Get started....

Additional test resources

The following functional tests can be adapted for USB Type-C to improve traditional USB scenarios.

Test caseDescriptionCategory
System BootConfirms that the product does not inhibit normal system boot.System, Dock, Device
System Power TransitionsTests whether the system's power transitions and wake-up capability from lower power states are not affected by the product.System, Dock, Device
Selective SuspendConfirms the selective suspend transitions.Dock, Device

The following stress tests can be adapted from the SuperMUTT test documentation to expand USB scenarios.

Scanntronik Mugrauer Usb Devices Driver Download For Windows 10 Offline

Test caseDescriptionCategory
System Power TransitionsTests product reliability after repetitive system power events.System, Dock, Device
Transfer EventsGenerates multiple transfer and connection events.System, Dock, Device
Plug and Play (PnP)Generates various PnP sequences.System, Dock, Device
Device TopologyTests a range of devices and topologies with the product.System, Dock, Device

Validating success or failure of the tests

Confirming charging and power

The onboard LCD on the USB Type-C ConnEx displays power (volts, amps, and direction). Confirm that it matches expectations from power sources plugged in and actively enabled with the USB Type-C ConnEx .

Confirming device addition on desktops

  1. Identify the USB host controller to which your device is connected.
  2. Make sure that the new device appears under the correct node in Device Manager.
  3. For USB 3.0 hubs connected to a USB 3.0 port, expect to see two hub devices: one enumerated at SuperSpeed and another at high speed.

Confirm device removal on desktops

  1. Identify your device in Device Manager.
  2. Perform the test step to remove the device from the system.
  3. Confirm that the device is no longer present in Device Manager.
  4. For a USB 3.0 hub, check that both devices (SuperSpeed and companion hubs) are removed. Failure to remove a device in this case may be a device failure and should be investigated by all components involved to triage the appropriate root cause.

Confirm device functionality

  • If the device is a USB hub, make sure that the devices that are downstream of the hub are functional. Verify that other devices can be connected to available ports on the hub.
  • If the device is an HID device, test its functionality. Make sure that a USB keyboard types, a USB mouse moves the cursor, and a gaming device is functional in the game controller's control panel.
  • A USB audio device must play and/or record sound.
  • A storage device must be accessible and should be able to copy a file 200MB or more in size.
  • If the device has multiple functions, such as scan & print, make sure to test both the scan and print functionality.
  • If the device is a USB Type-C device, confirm that the applicable USB and alternate modes are functional.

Using ETW to log issues

See How to capture a USB event trace with Logman

Reporting test results

Provide these details:

  • The list of tests (in order) that were performed before the failed test.
  • The list must specify the tests that have failed or passed.
  • Systems, devices, docks, or hubs that were used for the tests. Include make, model, and Web site so that we can get additional information, if needed.

Current Product Catalog:

Below you find the current product catalog of Scanntronik Mugrauer GmbH. Within you find all our data logger systems, sensors, measurement equipment and accessories. For more detailed information you can contact us personally at any time. Just give us a call or write us an email.

If you want to open and browse in our data logger product catalog, you need the free 'Adobe Reader'. You can download the reader on the Adobe© web site. Just click on the according link.

Product DescriptionReleaseDownload
Scanntronik Product CatalogIssue 2021 (German)16 MB (*.pdf file)
Scanntronik Product Catalog
- Neutral -
Without logo and prices
Issue 2021
(German - Neutral)
16 MB (*.pdf file)
Adobe© ReaderCurrent Release

Scanntronik Mugrauer Usb Devices Driver Download For Windows 10 Pro

Video Tutorials:

Scanntronik Mugrauer USB Devices Driver Download For Windows 10

Scanntronik Mugrauer Usb Devices Driver Download For Windows 10 Windows 7

The following video tutorials try to show and explain you the different features of our data loggers. You can easily download the different files and play them with your 'Windows Media Player':

TopicDownload
Video tutorial for the installation of the USB interface (German)13 MB (*.wmf file)
1. Basic video tutorial for the SoftFOX analysis software (German)11 MB (*.wmf file)

Software Updates:

Below you find the newest releases of our SoftFOX analysis software suitable for all Scanntronik data logger systems like the Thermofox Universal, Mini Ultra, Hygrofox, Room Climate Guard, etc.
The following 'SoftFOX' software release is a 32/64-bit application, especially designed for the 'Windows' operating systems: Microsoft Windows© XP, Vista, 7, 8, 10 or a newer version. Using the software with an older 'Windows' operating system is not recommended. 'Windows' is a registered trademark of Microsoft.
Please note, that some virus scanners (e.g. Kaspersky, ...) can interfere with the file download. In this case an error message like 'Error: The setup files are corrupted' can appear. Deactivate the virus scanner or use a different computer to download the file.

Description / Suitable forOperating SystemReleaseDownload
All Scanntronik Data Loggers incl. 32-bit and 64-bit-DriverWindows XP, Vista, 7, 8, 10 or newer3.05 / 1.0.0.57 English/German16 MB (*.exe file)
Installation Manual for the
USB - Interface
Windows XP, Vista, 7, 8, 10 or newer1.00
English
230 KB (*.pdf file)

Technical Documents, Theoretical Physics and Tools:

In this section you can download technical documents, manuals, papers and tools for our data logger systems and measurement equipment.

Tool / DocumentsTopicDownload
Online - SupportTool for the Scanntronik online support179 KB (*.zip file)
Excel Import / ExportData - Postprocessing with Excel (German)276 KB (*.doc file)
Theoretical PhysicsThe Physics of Hygrometry (German)230 KB (*.pdf file)

Technical Support and Service Team:

If you have any question or need help with one of our data loggers, just contact our technical support team via email. We always guarantee a maximum of motivation to answer your questions as soon as possible and to solve any possible problem.

Furthermore, you can always contact us via phone, so we can assist you personally.
You will find more information about how to contact Scanntronik Mugrauer GmbH here.