APCI-7300 Communications Port (COM5) Driver Download For Windows 10

-->

Versions supported

Aug 22, 2017 Download 1. Click Download File to download the file. When the File Download window is displayed, click Save to save the file to your hard drive. Browse to the location where you downloaded the file and double-click the new file. Read the information in the dialog window. Unzip USB Driver ZIP first, or the installation will fail. Connect the USB cable, then power on the IC-7100. Start the Device Manager Ports (COM & LPT) Make note of driver name 'Silicon Labs CP210x USB to UART Bridge' Make note of your port numbers (COM4 and COM5). Download Fldigi Software. USB Serial Port Driver WINDOWS 10 X64 & X86 All Problem Solved-Link 1: 2: You Mus.

  • Windows 10
  • Windows 8.1

Applies to

  • Device manufacturers of CDC Control devices

Microsoft-provided in-box driver (Usbser.sys) for your Communications and CDC Control device.

In Windows 10, the driver has been rewritten by using the Kernel-Mode Driver Framework that improves the overall stability of the driver.

  • Improved PnP and power management by the driver (such as, handling surprise removal).
  • Added power management features such as USB Selective Suspend.

In addition, UWP applications can now use the APIs provided by the new Windows.Devices.SerialCommunication namespace that allow apps to talk to these devices.

Usbser.sys installation

Load the Microsoft-provided in-box driver (Usbser.sys) for your Communications and CDC Control device.

Note

If you trying to install a USB device class driver included in Windows, you do not need to download the driver. They are installed automatically. If they are not installed automatically, contact the device manufacturer. For the list of USB device class driver included in Windows, see USB device class drivers included in Windows.

Windows 10

In Windows 10, a new INF, Usbser.inf, has been added to %Systemroot%Inf that loads Usbser.sys as the function device object (FDO) in the device stack. If your device belongs to the Communications and CDC Control device class, Usbser.sys is loaded automatically.You do not need to write your own INF to reference the driver. The driver is loaded based on a compatible ID match similar to other USB device class drivers included in Windows.

USBClass_02

USBClass_02&SubClass_02

  • If you want to load Usbser.sys automatically, set the class code to 02 and subclass code to 02 in the Device Descriptor. For more information, see USB communications device class. With this approach, you are not required to distribute INF files for your device because the system uses Usbser.inf.
  • If your device specifies class code 02 but a subclass code value other than 02, Usbser.sys does not load automatically. Pnp Manager tries to find a driver. If a suitable driver is not found, the device might not have a driver loaded. In this case, you might have to load your own driver or write an INF that references another in-box driver.
  • If your device specifies class and subclass codes to 02, and you want to load another driver instead of Usbser.sys, you have to write an INF that specifies the hardware ID of the device and the driver to install. For examples, look through the INF files included with sample drivers and find devices similar to your device. For information about INF sections, see Overview of INF Files.

Note

Microsoft encourages you to use in-box drivers whenever possible. On mobile editions of Windows, such as Windows 10 Mobile, only drivers that are part of the operating system are loaded. Unlike desktop editions, it is not possible to load a driver through an external driver package. With the new in-box INF, Usbser.sys is automatically loaded if a USB-to-serial device is detected on the mobile device.

Windows 8.1 and earlier versions

In Windows 8.1 and earlier versions of the operating system, Usbser.sys is not automatically loaded when a USB-to-serial device is attached to a computer. To load the driver, you need to write an INF that references the modem INF (mdmcpq.inf) by using the Include directive. The directive is required for instantiating the service, copying inbox binaries, and registering a device interface GUID that applications require to find the device and talk to it. That INF specifies 'Usbser' as a lower filter driver in a device stack.

The INF also needs to specify the device setup class as Modem to use mdmcpq.inf. Under the [Version] section of the INF, specify the Modem and the device class GUID. for details, see System-Supplied Device Setup Classes.

For more information, see this KB article.

Configure selective suspend for Usbser.sys

Starting in Windows 10, Usbser.sys supports USB Selective Suspend. It allows the attached USB-to-serial device to enter a low power state when not in use, while the system remains in the S0 state. When communication with the device resumes, the device can leave the Suspend state and resume Working state. The feature is disabled by default and can be enabled and configured by setting the IdleUsbSelectiveSuspendPolicy entry under this registry key:

To configure power management features of Usbser.sys, you can set IdleUsbSelectiveSuspendPolicy to:

  • '0x00000001': Enters selective suspend when idle, that is, when there are no active data transfers to or from the device.

  • '0x00000000': Enters selective suspend only when there are no open handles to the device.

That entry can be added in one of two ways:

  • Write an INF that references the install INF and add the registry entry in the HW.AddReg section.

  • Describe the registry entry in an extended properties OS feature descriptor. Add a custom property section that sets the bPropertyName field to a Unicode string, 'IdleUsbSelectiveSuspendPolicy' and wPropertyNameLength to 62 bytes. Set the bPropertyData field to '0x00000001' or '0x00000000'. The property values are stored as little-endian 32-bit integers.

    For more information, see Microsoft OS Descriptors.

Develop Windows applications for a USB CDC device

If you install Usbser.sys for the USB CDC device, here are the application programming model options:

  • Starting in Windows 10, a Windows app can send requests to Usbser.sys by using the Windows.Devices.SerialCommunication namespace. It defines Windows Runtime classes that can use to communicate with a USB CDC device through a serial port or some abstraction of a serial port. The classes provide functionality to discover such serial device, read and write data, and control serial-specific properties for flow control, such as setting baud rate, signal states.

  • In Windows 8.1 and earlier versions, you can write a Windows desktop application that opens a virtual COM port and communicates with the device. For more information, see:

    Win32 programming model:

    • .NET framework programming model:

Related topics

This section provides guidance how to establish serial connection between ESP32 and PC.

Connect ESP32 to PC¶

Apci-7300 Communications Port (com5) Driver Download For Windows 10 Kms

Connect the ESP32 board to the PC using the USB cable. If device driver does not install automatically, identify USB to serial converter chip on your ESP32 board (or external converter dongle), search for drivers in internet and install them.

Below are the links to drivers for ESP32 boards produced by Espressif:

Development Board

USB Driver

Remarks

Programmer board (w/o ESP32)

n/a

Use with ESP-Prog

n/a

Use with ESP-Prog

  • CP210x: CP210x USB to UART Bridge VCP Drivers

  • FTDI: FTDI Virtual COM Port Drivers

The drivers above are primarily for reference. Under normal circumstances, the drivers should be bundled with an operating system and automatically installed upon connecting one of the listed boards to the PC.

Check port on Windows¶

Check the list of identified COM ports in the Windows Device Manager. Disconnect ESP32 and connect it back, to verify which port disappears from the list and then shows back again.

Apci-7300 Communications Port (com5) Driver Download For Windows 10 32-bit

Communications

Figures below show serial port for ESP32 DevKitC and ESP32 WROVER KIT

USB to UART bridge of ESP32-DevKitC in Windows Device Manager

Two USB Serial Ports of ESP-WROVER-KIT in Windows Device Manager

Check port on Linux and macOS¶

To check the device name for the serial port of your ESP32 board (or external converter dongle), run this command two times, first with the board / dongle unplugged, then with plugged in. The port which appears the second time is the one you need:

Linux

macOS

Note

macOS users: if you don’t see the serial port then check you have the USB/serial drivers installed as shown in the Getting Started guide for your particular development board. For macOS High Sierra (10.13), you may also have to explicitly allow the drivers to load. Open System Preferences -> Security & Privacy -> General and check if there is a message shown here about “System Software from developer …” where the developer name is Silicon Labs or FTDI.

Adding user to dialout on Linux¶

The currently logged user should have read and write access the serial port over USB. On most Linux distributions, this is done by adding the user to dialout group with the following command:

on Arch Linux this is done by adding the user to uucp group with the following command:

Make sure you re-login to enable read and write permissions for the serial port.

Apci-7300 Communications Port (com5) Driver Download For Windows 10 64

Verify serial connection¶

Now verify that the serial connection is operational. You can do this using a serial terminal program by checking if you get any output on the terminal after reseting ESP32.

Windows and Linux¶

In this example we will use PuTTY SSH Client that is available for both Windows and Linux. You can use other serial program and set communication parameters like below.

Run terminal, set identified serial port, baud rate = 115200, data bits = 8, stop bits = 1, and parity = N. Below are example screen shots of setting the port and such transmission parameters (in short described as 115200-8-1-N) on Windows and Linux. Remember to select exactly the same serial port you have identified in steps above.

Setting Serial Communication in PuTTY on Linux

Then open serial port in terminal and check, if you see any log printed out by ESP32. The log contents will depend on application loaded to ESP32, see Example Output.

Note

Close the serial terminal after verification that communication is working. If you keep the terminal session open, the serial port will be inaccessible for uploading firmware later.

macOS¶

To spare you the trouble of installing a serial terminal program, macOS offers the screen command.

  • As discussed in Check port on Linux and macOS, run:

  • You should see similar output:

  • The output will vary depending on the type and the number of boards connected to your PC. Then pick the device name of your board and run:

    Replace device_name with the name found running ls/dev/cu.*.

  • What you are looking for is some log displayed by the screen. The log contents will depend on application loaded to ESP32, see Example Output. To exit the screen session type Ctrl-A + .

Note

Do not forget to exit the screen session after verifying that the communication is working. If you fail to do it and just close the terminal window, the serial port will be inaccessible for uploading firmware later.

Example Output¶

An example log by ESP32 is shown below. Reset the board if you do not see anything.

If you can see readable log output, it means serial connection is working and you are ready to proceed with installation and finally upload of application to ESP32.

Note

For some serial port wiring configurations, the serial RTS & DTR pins need to be disabled in the terminal program before the ESP32 will boot and produce serial output. This depends on the hardware itself, most development boards (including all Espressif boards) do not have this issue. The issue is present if RTS & DTR are wired directly to the EN & GPIO0 pins. See the esptool documentation for more details.

If you got here from Step 6. Connect Your Device when installing s/w for ESP32 development, then you can continue with Step 7. Configure.